Average rating on the App Store. Apple doesn't publish how many ratings each star has.
This app isn't in any of our charts yet.
New for US homes (NEC): • Pre-Inspection Checklist: what the inspector checks, with NEC sections. Kitchen is free; the other jobs (new house, old house, generator and solar), photos, the fix list and the PDF are Pro • Code in Your State, free: which NEC applies and whether you may do the work yourself • New Pro: Panel Check and House Service Size (NEC 220.82) • Fixes: A/C and heat pumps at 100 % in the panel load, 200/208 V motors, Undo • 12 languages
Size the wire and the breaker for a circuit in seconds, by NEC 310.16 or IEC 60364. The answer stays on screen while you type, voltage drop is checked and every step is shown for the inspector. Then plan the whole panel, print the circuit directory for the door, and send the client a PDF with your business name and license number on top. Free: Wire Size, Voltage Drop, Power & Ohm's Law, Conduit & Box Fill, the kitchen inspection checklist, Code in Your State, the reference tables and 3 projects with their PDF reports. Pro unlocks every calculator and unlimited projects; try any on an example first. No ads, no account. Every calculation follows IEC 60364 (mm², meters, 230/400 V) or the 2023 NEC / NFPA 70 (AWG, feet, 120/208/240/480 V). The app picks the standard for your country, and you can switch with one tap. WHY ELECTRICIANS USE IT • Real tables, not rough formulas: ampacity, temperature and grouping factors, NEC 310.16 at 75 °C FOR US HOMES (NEC) • Pre-Inspection Checklist: what the inspector checks, with NEC sections, notes and photos. Kitchen is free; the other 7 jobs (new or old house, generator, solar and more), photos and the PDF are Pro • Code in Your State, free: which NEC your state enforces and whether you may do the work yourself • House Service Size (NEC 220.82) and Panel Check: does each breaker protect its wire? (Pro) FREE • Wire Size: Ib ≤ In ≤ Iz with derating, then upsized for voltage drop, plus the grounding conductor (NEC 250.122 or IEC Table 54.2) • Voltage Drop for AC and DC: percent, voltage at the load, smallest size, parallel runs • Power & Ohm's Law: kW ↔ A ↔ kVA for DC, single and three phase • Conduit & Box Fill (NEC Chapter 9, 314.16) • Reference: typical circuits, wire colors, ampacity tables, breaker curves, formulas PRO • Panel Planner: list the circuits and get breakers, RCDs, phase balance, a DIN-rail layout, a materials list that becomes a job quote, and a printable panel directory (NEC 408.4) • EV Charger & Heat Pump Check (NEC 220.83 / 220.87): will the service take it? With a load sheet for the permit • Wire Ampacity and Max Wire Length • Motor Circuit: starting current, breaker, cable and overload • Transformer & Fault Level, Ground-Fault Loop (Zs) • Selectivity, Grounding Conductor & Withstand, Ground Rod resistance • Test Results: insulation, Zs, RCD and polarity per circuit (IEC 60364-6) • Underfloor Heating: cable or mat, pitch, thermostat and breaker • Load Schedule with demand factors and phase balance • Power Factor Correction (kvar and µF) • Solar PV Strings: Voc in frost, Vmp in heat, MPPT limits • Backup Power: inverter, battery and generator • Voltage Stabilizer, Lighting Design, Energy Cost, Battery & UPS • AWG ↔ mm² including aluminum to copper replacement, Unit Converter • Unlimited projects with client, address and notes, and a PDF report with your business name and license number MADE FOR THE JOB • What are you connecting? Range, dryer, EV charger: wire and breaker in one tap • Dark and light themes, works offline • Back up your projects to a file and restore them on a new phone • 12 languages Pro is an auto-renewing subscription (yearly or monthly, as shown in the app); the yearly plan may start with a free trial. Payment is charged to your Apple ID when you confirm the purchase (when the free trial ends, if you start one). Subscriptions renew automatically unless cancelled at least 24 hours before the end of the current period. You can manage or cancel your subscription in your Apple ID settings at any time. Calculations are a design aid. Always check the final design against the regulations that apply where you work. NEC® and NFPA 70® are registered trademarks of the National Fire Protection Association. Electrician Calc is not affiliated with or endorsed by NFPA. Terms of Use: https://andronaft-2.github.io/app_politics_and_terms/electrician-calc/terms.html Privacy Policy: https://andronaft-2.github.io/app_politics_and_terms/electrician-calc/privacy.html